A.2 Power Ratings
u

Three-Phase 400 V Class Drive Models 4A0208 to 4A1200

Item
Drive Models
Maximum Applicable Motor
<1>
Capacity (HP)
Input Current (A)
Rated Voltage
Input
Rated Frequency
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Input Power (kVA)
Rated Output Capacity
<4>
(kVA)
Rated Output Current
(A)
Output
Overload Tolerance
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions,
and power supply impedance.
<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
240
Table A.7 Power Ratings Continued (Three-Phase 400 V Class)
4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 4A0930 4A1200
ND Rating
150
HD Rating
125-150
ND Rating
207
<2>
HD Rating
170
ND Rating
189
HD Rating
155
<5>
189
ND Rating
137
HD Rating
<6>
<5>
208
ND Rating
180
HD Rating
<6>
User-adjustable between 1 and 10 kHz
Three-phase: 380 to 480 Vac (proportional to input voltage)
Specification
200
250
300
150
200
250
248
300
346
207
248
300
Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
227
274
316
189
227
274
227
274
316
165
198
232
<6>
<6>
<6>
250
296
362
216
260
304
<6>
<6>
<6>
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
400 Hz (user-adjustable)
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
350
400-450 500-550
400-450-
300
350
500
410
465
657
346
410
584
-15 to 10%
±5%
375
425
601
316
375
534
375
425
601
282
343
461
<6>
<5>
<5>
414
515
675
370
450
605
<7>
<5>
<5>
User-adjustable between 1 and 5 kHz
750
1000
650
900
922
1158
830
1031
<3>
843
1059
759
943
843
1059
617
831
<5>
<5>
930
1200
810
1090
<5>
<5>
0.95 ×
[input voltage]