D3: Jump Frequency; D4: Frequency Reference Hold And Up/Down 2 Function - YASKAWA A1000 Series Quick Start Manual

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.4 d: References
u

d3: Jump Frequency

No.
(Addr.
Name
Hex)
d3-01
Jump Frequency 1
(0294)
d3-02
Jump Frequency 2
(0295)
d3-03
Jump Frequency 3
(0296)
d3-04
Jump Frequency Width Jump Bandwidth
(0297)
<1> Default setting is determined by parameter A1-02, Control Mode Setting.
<2> Default setting is 0.0% and setting range is 0.0 to 100.0% in AOLV/PM or CLV/PM.
<3> Default setting is 1.0% and setting range is 0.0 to 40.0% in AOLV/PM and CLV/PM.
u

d4: Frequency Reference Hold and Up/Down 2 Function

No.
(Addr.
Name
Hex)
d4-01
Frequency Reference
(0298)
Hold Function Selection
d4-03
(02AA) Frequency Reference
Bias Step (Up/Down 2)
d4-04
Frequency Reference
(02AB)
Bias Accel/Decel (Up/
Down 2)
d4-05
Frequency Reference
(02AC)
Bias Operation Mode
Selection (Up/Down 2)
d4-06
Frequency Reference
(02AD)
Bias (Up/Down 2)
d4-07
Analog Frequency
(02AE)
Reference Fluctuation
Limit (Up/Down 2)
d4-08
Frequency Reference
(02AF)
Bias Upper Limit (Up/
Down 2)
d4-09
Frequency Reference
(02B0)
Bias Lower Limit (Up/
Down 2)
268
LCD Display
Eliminates problems with resonant vibration of the motor/
machine by avoiding continuous operation in predefined
frequency ranges. The drive accelerates and decelerates the
Jump Freq 1
motor through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
Eliminates problems with resonant vibration of the motor/
machine by avoiding continuous operation in predefined
frequency ranges. The drive accelerates and decelerates the
Jump Freq 2
motor through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
Eliminates problems with resonant vibration of the motor/
machine by avoiding continuous operation in predefined
frequency ranges. The drive accelerates and decelerates the
Jump Freq 3
motor through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
Sets the dead-band width around each selected prohibited
frequency reference point.
LCD Display
0: Disabled. Drive starts from zero when the power is switched
Fref Hold Sel
on.
0: Disabled
1: Enabled. At power up, the drive starts the motor at the Hold
1: Enabled
frequency that was saved.
Sets the bias added to the frequency reference when the Up 2
and Down 2 digital inputs are enabled (H1-oo = 75, 76).
Up/Dn 2 Step Lvl
0: Use selected accel/decel time.
Up/Dn 2 Ramp Sel
1: Use accel/decel time 4 (C1-07 and C1-08).
0: Sel Acc/Dec Time
1: Acc/Dec Time 4
0: Bias value is held if no input Up 2 or Down 2 is active.
Up/Dn 2 Bias Sel
1: When the Up 2 reference and Down 2 reference are both on
0: Hold Bias Value
or both off, the applied bias becomes 0. The specified accel/
1: Reset Bias Value
decel times are used for acceleration or deceleration.
The Up/Down 2 bias value is saved in d4-06 when the
Up/Dn 2 Bias Lvl
frequency reference is not input by the digital operator. Set as
a percentage of the maximum output frequency.
Limits how much the frequency reference is allowed to change
while an input terminal set for Up 2 or Down 2 is enabled. If
the frequency reference changes for more than the set value,
Up/Dn 2 FluctLim
then the bias value is held and the drive accelerates or
decelerates to the frequency reference. Set as a percentage of
the maximum output frequency.
Sets the upper limit for the bias and the value that can be saved
in d4-06. Set as a percentage of the maximum output frequency.
Up/Dn 2 UpperLim
Sets the lower limit for the bias and the value that can be saved
in d4-06. Set as a percentage of the maximum output frequency.
Up/Dn 2 LowerLim
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Description
Description
Values
Page
<1> <2>
Default:
<2>
Min.: 0.0
<2>
Max.: 400.0
<1> <2>
Default:
<2>
Min.: 0.0
<2>
Max.: 400.0
<1> <2>
Default:
<2>
Min.: 0.0
<2>
Max.: 400.0
<1> <3>
Default:
<3>
Min.: 0.0
<3>
Max.: 20.0
Values
Page
Default: 0
Range: 0, 1
Default: 0.00 Hz
Min.: 0.00
Max.: 99.99
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0.0%
Min.: -99.9
Max.: 100.0
Default: 1.0%
Min.: 0.1
Max.: 100.0
Default: 100.0%
Min.: 0.0
Max.: 100.0
Default: 0.0%
Min.: -99.9
Max.: 0.0