B.2 b: Application
B.2 b: Application
Application parameters configure the source of the Run command, DC Injection Braking, Speed Search, timer functions, PID
control, the Dwell function, Energy Savings, and a variety of other application-related settings.
u

b1: Operation Mode Selection

No.
(Addr.
Name
Hex)
b1-01
Frequency Reference
(0180)
Selection 1
b1-02
Run Command
(0181)
Selection 1
b1-03
Stopping Method
(0182)
Selection
b1-04
Reverse Operation
(0183)
Selection
Action Selection below
b1-05
Minimum Output
(0184)
Frequency
b1-06
Digital Input Reading
(0185)
b1-07
LOCAL/REMOTE Run
(0186)
Selection
b1-08
Run Command Selection
(0187)
in Programming Mode
b1-14
Phase Order Selection
(01C3)
b1-15
Frequency Reference
(01C4)
Selection 2
b1-16
Run Command
(01C5)
Selection 2
252
LCD Display
Ref Source 1
0: Digital operator
0: Operator
1: Analog input terminals
1: Analog Input
2: MEMOBUS/Modbus communications
2: Serial Com
3: Option PCB
3: Option PCB
4: Pulse input (terminal RP)
4: Pulse Input
Run Source 1
0: Digital operator
0: Operator
1: Digital input terminals
1: Digital Inputs
2: MEMOBUS/Modbus communications
2: Communication
3: Option PCB
3: Option PCB
Stopping Method
0: Ramp to stop
0: Ramp to Stop
1: Coast to stop
1: Coast to Stop
2: DC Injection Braking to stop
2: DCInj to Stop
3: Coast with timer
3: Coast w/Timer
Reverse Oper
0: Reverse enabled.
0: Reverse Enabled
1: Reverse disabled.
1: Reverse Disabled
0: Operates according to frequency reference (E1-09 is
Zero-Speed Oper
disabled).
0: RUN at Freq Ref
1: Output shuts off (coast to stop if less than E1-09).
1: STOP
2: Operates according to E1-09 (frequency reference set to
2: RUN at Min Freq
E1-09).
RUN at Zero PRM
3: Zero speed (frequency reference becomes zero when less than
E1-09).
0: Input status is read once and processed immediately (for
Cntl Input Scans
quicker response)
0: 1 Scan
1: Input is read twice and processed only if the status is the same
1: 2 Scans
in both readings (robust against noisy signals)
0: An external Run command must be cycled at the new source
LOC/REM Dur Run
in order to be activated.
0: Cycle Extrn RUN
1: An external Run command at the new source is accepted
1: Accept Extrn RUN
immediately.
RUN dur PRG Mode
0: Run command is not accepted while in Programming Mode.
0: Run
1: Run command is accepted while in Programming Mode.
Disabled@PRG
2: Prohibit entering Programming Mode during run.
1: Run Enabled@PRG
2: Prg only @ Stop
Rotation Sel
0: Standard
0: Standard
1: Switch phase order (reverses the direction of the motor)
1: SwitchPhaseOrder
Enabled when an input terminal set for "External reference"
Ref Source 2
(H1-oo = 2) closes.
0: Operator
0: Digital operator
1: Analog Input
1: Terminals (analog input terminals)
2: Serial Com
2: MEMOBUS/Modbus communications
3: Option PCB
3: Option card
4: Pulse Input
4: Pulse train input
Enabled when a terminal set for "External reference"
Run Source 2
(H1-oo = 2) closes.
0: Operator
0: Digital operator
1: Digital Inputs
1: Digital input terminals
2: Communication
2: MEMOBUS/Modbus communications
3: Option PCB
3: Option card
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Description
Values
Page
Default: 1
136
Range: 0 to 4
Default: 1
138
Range: 0 to 3
Default: 0
Range: 0 to 3
138
<1>
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 3
Default: 1
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 2
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 4
Default: 0
Range: 0 to 3