Auto-Tuning Interruption And Fault Codes - YASKAWA A1000 Series Quick Start Manual

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

Input
Input Value
Unit
Param.
Control Mode
A1-02
Motor Code
T2-02
(Hex.)
PG Number of
Pulses Per
T2-16
ppr
Revolution
deg
Z Pulse Offset
T2-17
(mech.) YES
<1> Input the motor code when using a Yaskawa motor. Select "FFFF" when using a motor from another manufacturer.
<2> Input data is needed for CLV/PM only.
<3> Dependent upon T2-13 setting.
n
Inertia Tuning and Speed Control Loop Auto-Tuning
Inertia Tuning can be performed when the drive is using CLV control for either IM or PM motors. Inertia Tuning automatically
calculates load and motor inertia, and optimizes settings related to the KEB Ride-Thru function (KEB 2) and Feed Forward
control.
ASR Gain Auto-Tuning performs the same operation as Inertia Tuning, while also optimizing speed control loop settings.
Type
IM
Motor
Inertia Tuning
PM
Motor
IM
Motor
ASR Gain Auto-
Tuning
PM
Motor
Note:
Inertia Tuning and ASR Gain Auto-Tuning may not be available when gears are between the machine and the motor shaft.
Table 4.33
explains the data that must be entered to perform the Inertia Tuning and ASR Gain Auto-Tuning.
Tuning for Permanent Magnet Motors on page 165
Input Value
Control Mode
Test signal frequency
Test signal amplitude
Motor inertia
System response frequency
u

Auto-Tuning Interruption and Fault Codes

If tuning results are abnormal or the STOP key is pressed before completion, Auto-Tuning will be interrupted and a fault code
will appear on the digital operator.
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
0
Motor Parameter
Stationary
Settings
5, 6, 7
5
6, 7
<1>
<1>
<1>
YES
<2>
YES
<2>
YES
<2>
<2>
Table 4.32 Inertia and Speed Control Loop Tuning
Setting
Control Mode
T1-01 = 8
CLV
T2-01 = 8
CLV/PM
T1-01 = 9
CLV
T2-01 = 9
CLV/PM
Table 4.33 Auto-Tuning Input Data
Input Parameter
A1-02
T3-01
T3-02
T3-03
T3-04
Tuning Type (T2-01)
2
3
1
Stationary
Z-Pulse
Stator Resis.
Offset
5
6, 7
5, 6, 7
7
YES
<2>
YES
<2>
Application Conditions and Benefits
Allows the motor to rotate at a certain speed and applies a test signal. The response
to the test signal is analyzed and the necessary adjustments are made to parameters
controlling the Feed Forward and KEB Ride-Thru functions (KEB 2, L2-29 = 1).
Performs the same operation as Inertia Tuning, while also adjusting the ASR gain
according to the test signal response.
for details.
Unit
Hz
rad
2
kgm
Hz
4.7 Auto-Tuning
11
13
Back EMF
High Freq.
Const.
Injection
7
6, 7
Refer to Auto-
Tuning Type (T1-01 or T2-01)
8
Inertia Tuning
ASR Gain Tuning
3, 7
YES
YES
YES
14
Rotational
5
6
7
YES
9
3, 7
YES
YES
YES
YES
4
167