YASKAWA A1000 Series Quick Start Manual page 187

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

Digital Operator Display
Cause
The option card connection to port CN5-A is
faulty
Digital Operator Display
oFA03 to oFA06
to
oFA10, oFA11
,
oFA12 to oFA17
to
to
oFA30 to oFA43
Cause
Option card or hardware is damaged
to
oFb03 to oFb11
to
oFb12 to oFb17
to
oFC03 to oFC11
oFC12 to oFC17
to
oFC50 to oFC55
to
Digital Operator Display
Cause
Surrounding temperature is too high
Load is too heavy
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Option Card Fault at Option Port CN5-A
oFA01
Option not properly connected
• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed properly.
• If the option is not a communication option card, try to use the card in a different option port. If the
option card works properly in a different option port, CN5-A is damaged, and the drive requires
replacement. If the error persists (oFb01 or oFC01 occur), replace the option card.
Option Card Error Occurred at Option Port CN5-A
Option Card Connection Error (CN5-A)
Communication Option Card Connection Error (CN5-A)
• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa
representative for instructions on replacing the control board.
Option Card Fault at Option Port CN5-B
oFb00
Option compatibility error
Option Card Fault at Option Port CN5-B
oFb01
Option not properly connected
Option Card Fault at Option Port CN5-B
oFb02
Same type of option card is currently connected
Option card error occurred at Option Port CN5-B
Option Card Connection Error at Option Port CN5-C
oFC00
Option compatibility error
Option Card Fault at Option Port CN5-C
oFC01
Option not properly connected
Option Card Fault at Option Port CN5-C
oFC02
Same type of option card is currently connected
Option Card Error Occurred at Option Port CN5-C
Option Card Error Occurred at Option Port CN5-C
Heatsink Overheat
oH
The heatsink temperature exceeded the overheat pre-alarm level set to L8-02. The default value for L8-02
is determined by drive model selection (o2-04).
• Check the temperature surrounding the drive. Verify temperature is within drive specifications.
• Improve the air circulation within the enclosure panel.
• Install a fan or air conditioner to cool the surrounding area.
• Remove anything near the drive that might be producing excessive heat.
• Measure the output current.
• Decrease the load.
• Lower the carrier frequency selection (C6-02).
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
5.2 Fault Detection
5
187

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents