O3: Copy Function; O4: Maintenance Monitor Settings - YASKAWA A1000 Series Quick Start Manual

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
o2-04
Drive Model Selection
(0508)
Frequency Reference
o2-05
Setting Method
(0509)
Selection
Operation Selection
o2-06
when Digital Operator is
(050A)
Disconnected
Motor Direction at
o2-07
Power Up when Using
(0527)
Operator
o2-09
(050D)
o2-19
Selection of Parameter
(061F)
Write during Uv
<1>
<1> Available in drive software versions PRG: 1019 and later.
u

o3: Copy Function

No.
(Addr.
Name
Hex)
o3-01
Copy Function Selection
(0515)
o3-02
Copy Allowed Selection
(0516)
u

o4: Maintenance Monitor Settings

No.
(Addr.
Name
Hex)
o4-01
Cumulative Operation
(050B)
Time Setting
o4-02
Cumulative Operation
(050C)
Time Selection
o4-03
Cooling Fan Operation
(050E)
Time Setting
o4-05
Capacitor Maintenance
(051D)
Setting
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
LCD Display
Enter the drive model. Setting required only if installing a new
Inverter Model #
control board.
Oper Ref Method
0: ENTER key must be pressed to enter a frequency reference.
0: Disabled
1: ENTER key is not required. The frequency reference can be
1: Enabled
adjusted using the up and down arrow keys only.
Oper Discon Det
0: The drive continues operating if the digital operator is
0: Disabled
disconnected.
1: Enabled
1: An oPr fault is triggered and the motor coasts to stop.
0: Forward
For/RevSel@PwrUp
1: Reverse
0: Forward
This parameter requires assigning drive operation to the digital
1: Reverse
operator.
Factory use.
Selects whether parameter settings can be changed during a DC
bus undervoltage condition. To be used with 24 V Power
Supply option (PS-A10L, PS-A10H) revision B or later.
0: Disabled
ParameterSet Sel
1: Enabled
0: Disabled
1: Enabled
Note:
LCD Display
0: Copy select
1: INV → OP READ (Read parameters from the drive, saving
COPY SELECT
them onto the digital operator).
0: COPY SELECT
2: OP → INV WRITE (Copy parameters from the digital
1: INV→OP READ
operator, writing them to the drive).
2: OP→INV WRITE
3: OP → INV VERIFY (Verify that parameter settings match
3: OP←→INV
the data saved on the operator).
VERIFY
To read the drive parameter settings into the digital operator,
set o3-02 to 1 (to allow reading).
Selects whether the read operation (o3-01 = 1) is enabled or
Read Allowable
disabled.
0: Disabled
0: Read operation prohibited
1: Enabled
1: Read operation allowed
LCD Display
Sets the value for the cumulative operation time of the drive in
DrvElapsTimeCnt
units of 10 h.
ElapsTimeCntSet
0: Logs power-on time
0: Power-On Time
1: Logs operation time when the drive output is active (output
1: Running Time
operation time).
Sets the value of the fan operation time monitor U4-03 in units
FanElapsTimeCn
of 10 h.
Sets the point at which the cumulative timing for the main
circuit capacitor maintenance starts.
BusCap Maint Set
View monitor U4-05 to determine when the capacitors may
require replacement.
B.10 o: Operator-Related Settings
Description
Enabling this function may trigger a CPF06 fault
when used with a 24 V Power Supply option
revision earlier than B, as the parameter changes
might not occur correctly.
Description
Description
Values
Page
Default:
Determined by
drive capacity
Default: 0
Range: 0, 1
Default: 1
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Values
Page
Default: 0
Range: 0 to 3
Default: 0
Range: 0, 1
Values
Page
Default: 0
Min.: 0
Max.: 9999
Default: 0
Range: 0, 1
Default: 0
Min.: 0
Max.: 9999
Default: 0%
Min.: 0
Max.: 150
B
313