YASKAWA A1000 Series Quick Start Manual page 200

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

5.3 Alarm Detection
Digital Operator Display
Cause
IGBTs have reached 50% of their expected
performance life.
Digital Operator Display
Cause
Surrounding temperature is too high
Internal cooling fan has stopped.
Airflow around the drive is restricted.
<1>
<1> Detected in models 4A0930 and 4A1200.
200
IGBT Maintenance Time (50%)
IGBTs have reached 50% of their expected performance life.
LT-4
Note:
The signal closes when the maintenance period ends if H2-oo = 2F. The signal will not close
if H2-oo = 10.
Check the load, carrier frequency, and output frequency.
Heatsink Overheat
oH
The temperature of the heatsink exceeded the overheat pre-alarm level set to L8-02 (90-100 °C). Default
value for L8-02 is determined by drive model selection (o2-04).
• Check the surrounding temperature.
• Improve the air circulation within the enclosure panel.
• Install a fan or air conditioner to cool surrounding area.
• Remove anything near drive that may cause extra heat.
• Replace the cooling fan.
• After replacing the drive, set parameter o4-03 to 0 to reset the cooling fan operation time.
• Provide proper installation space around the drive as indicated in the manual.
Orientation and Spacing on page 28
• Allow for the proper space and ensure that there is sufficient circulation around the control panel.
• Check for dust or other foreign materials clogging the cooling fan.
• Clear debris caught in the fan that restricts air circulation.
Heatsink Overheat Warning
oH2
"Heatsink Overheat Warning" was input to a multi-function input terminal, S1 through S8 (H1-oo= B).
Motor Overheat
oH3
The motor overheat signal entered to a multi-function analog input terminal exceeded the alarm level (H3-02,
H3-06 or H3-10 = E).
Motor Overheat (NTC Input)
oH5
The motor temperature exceeded the level set to L1-16 (or L1-18 for motor 2)
Overtorque 1
oL3
Drive output current (or torque in OLV, CLV, AOLV/PM, and CLV/PM) was greater than L6-02 for longer
than the time set to L6-03.
Overtorque 2
oL4
Drive output current (or torque in OLV, CLV, AOLV/PM, CLV/PM) was greater than L6-05 for longer than
the time set to L6-06.
Mechanical Weakening Detection 1
oL5
Overtorque occurred, matching the conditions specified in L6-08.
Overspeed
oS
The motor speed feedback exceeded the F1-08 setting.
DC Bus Overvoltage
The DC bus voltage exceeded the trip point.
ov
• For 200 V class drives: approximately 410 V
• For 400 V class drives: approximately 820 V (740 V when E1-01 is less than 400)
• For 600 V class drives: approximately 1040 V
Minor Fault Name
Possible Solutions
Minor Fault Name
Possible Solutions
for details.
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide