A.2 Power Ratings
u

Three-Phase 600 V Class Drive Models 5A0041 to 5A0099

Drive Models
Maximum Applicable Motor Capacity (HP)
<1>
Input Current (A)
Input
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Input Power (kVA)
Rated Output Capacity (kVA)
Rated Output Current (A)
Output
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 575 V.
<4> Carrier frequency can be increased to 2 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<5> Carrier frequency can be increased to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<6> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
242
Table A.9 Power Ratings Continued (Three-Phase 600 V Class)
Item
ND Rating
HD Rating
ND Rating
<2>
HD Rating
Rated Voltage
Rated Frequency
ND Rating
HD Rating
ND Rating
<3>
HD Rating
ND Rating
HD Rating
Overload Tolerance
Carrier Frequency
5A0041
5A0052
40
50
25-30
40
44
54
33
44
Three-phase 500 to 600 Vac 50/60 Hz
50
62
38
50
<4>
41
52
32
41
<5>
<5>
<4>
41
52
32
41
<5>
<5>
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
User adjustable between 2 and 10 kHz
Three-phase 500 to 600 Vac (proportional to input voltage)
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Specification
5A0062
5A0077
60
75
50-60
50-60
66
80
54
66
-10 (-15) to +10%
±5%
75
91
62
75
62
77
52
62
<5>
<5>
62
77
52
62
<5>
<5>
400 Hz (user-set)
5A0099
100
75
108
80
123
91
99
77
<6>
99
77
<6>
User
adjustable
between 2 and
8 kHz

Hide quick links:

Advertisement

Table of Contents
loading