YASKAWA A1000 Series Quick Start Manual page 321

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
U1-11
(004A) Output Terminal Status Output Term Sts
U1-12
(004B) Drive Status
U1-13
(004E) Terminal A1 Input Level Term A1 Level
U1-14
Terminal A2 Input Level Term A2 Level
(004F)
U1-15
Terminal A3 Input Level Term A3 Level
(0050)
U1-16
Output Frequency after
(0053)
Soft Starter
U1-17
DI-A3 Input Status
(0058)
U1-18
oPE Fault Parameter
(0061)
U1-19
MEMOBUS/Modbus
(0066)
Error Code
U1-21
AI-A3 Terminal V1
(0077)
Input Voltage Monitor
U1-22
AI-A3 Terminal V2
(072A)
Input Voltage Monitor
U1-23
AI-A3 Terminal V3
(072B)
Input Voltage Monitor
U1-24
Input Pulse Monitor
(007D)
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Displays the output terminal status.
U1 - 11=
Displays the drive operation status.
U1 - 12=
Int Ctl Sts 1
Displays the signal level to analog input terminal A1.
Displays the signal level to analog input terminal A2.
Displays the signal level to analog input terminal A3.
Displays output frequency with ramp time and S-curves. Units
SFS Output
determined by o1-03.
Displays the reference value input from the DI-A3 option card.
Display will appear in hexadecimal as determined by the digital
DI Opt Status
card input selection in F3-01.
3FFFF: Set (1 bit) + sign (1 bit) + 16 bit
Displays the parameter number that caused the oPE02 or oPE08
OPE Error Code
operation error.
Displays the contents of a MEMOBUS/Modbus error.
U1 - 19=
Transmit Err
Displays the input voltage to terminal V1 on analog input card
AI Opt Ch1 Level
AI-A3.
Displays the input voltage to terminal V2 on analog input card
AI Opt Ch2 Level
AI-A3.
Displays the input voltage to terminal V3 on analog input card
AI Opt Ch3 Level
AI-A3.
Displays the frequency to pulse train input terminal RP.
Term RP Inp Freq
Description
00000000
1
Multi-Function
Digital Output
(terminal M1-M2)
1
Multi-Function
Digital Output
(terminal M3-M4)
1
Multi-Function
Digital Output
(terminal M5-M6)
0
Not Used
1
Fault Relay
(terminal MA-MC closed
MA-MC open)
00000000
1
During run
1
During zero-speed
1
During REV
1
During fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
00000000
1
CRC Error
1
Data Length Error
0
Not Used
1
Parity Error
1
Overrun Error
1
Framing Error
1
Timed Out
0
Not Used
B.13 U: Monitors
Analog
Unit
Output Level
No signal
output available
No signal
output available
10 V: 100%
0.1%
(-10 to +10 V)
10 V: 100%
0.1%
(-10 to +10 V)
10 V: 100%
0.1%
(-10 to +10 V)
10 V: Max
frequency
0.01 Hz
(-10 to +10 V)
No signal
output available
No signal
output available
No signal
output available
10 V: 100%
0.1%
(-10 to +10 V)
10 V: 100%
0.1%
(-10 to +10 V)
10 V: 100%
0.1%
(-10 to +10 V)
Determined by
1 Hz
B
H6-02
321

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents