Commissioning with CANopen
4.1 Requirements for commissioning
The CU305 CAN uses 9-pin Sub D X126 connectors for the connection to the CAN bus
system.
Do NOT connect a PROFIBUS cable
Connecting a PROFIBUS cable to CAN connector X126 is highly likely to damage the
CANopen interface of the CU305 beyond repair.
You can use the connectors as inputs or outputs. Unused pins are plated through.
The following baud rates (among others) are supported: 10, 20, 50, 125, 250, 500,
800 kBaud, and 1 Mbaud.
The PC with STARTER is connected to serial interface X22 (RS232).
4.1.4

CAN bus interface X126

Connector assignment of the CANopen interface X126 on S110
Table 4- 1
Type: 9-pin SUB-D male
68
WARNING
CAN bus interface X126
Pin
1
2
3
4
5
6
7
8
9
Designation
Reserved
CAN_L
CAN_GND
Reserved
CAN_SHLD
CAN_GND
CAN_H
Reserved
Reserved
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Technical specifications
CAN signal (dominant low)
CAN ground
Optional shield
CAN ground
CAN signal