9.5 Communication using USS
Parameter identifier (PKE), first word
The parameter identifier (PKE) is always a 16-bit value.
Figure 9-50
● Bits 0 to 10 (PNU) contain the remainder of the parameter number (value range 1 to
For parameter numbers ≥ 2000, an offset must be added that is defined using the upper bits
of the IND byte.
● Bit 11 (SPM) is reserved and always = 0.
● Bits 12 to 15 (AK) contain the request or response identifier.
The significance of the request identifier for request telegrams (master → inverter) is
described in the following table.
Table 9- 45
Request
identifier
0
1
2
3
4
6
7
8
1) The required element of the parameter description is specified in IND (second word).
2) Identifier 1 is identical to identifier 6, ID 2 is identical to 7, and 3 is identical to 8. We recommend
that you use identifiers 6, 7, and 8.
The significance of the response identifier for response telegrams (inverter → master) is
described in the following table. The request identifier determines which response identifiers
are possible.
646
PKE structure
61999).
Request identifier (master → inverter)
No request
Request parameter value
Change parameter value (word)
Change parameter value (double word)
Request descriptive element
Request parameter value
Change parameter value (word)
Change parameter value (double word)
Description
1)
1) 2)
1) 2)
1) 2)
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Response
identifier
Positive
Negative
0
7
1 / 2
7
1
7
2
7
3
7
4 / 5
7
4
7
5