Siemens Sinamics S110 Function Manual page 555

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Bit
Meaning
7
No thermal overload in power unit
alarm
8
Speed setp - act val deviation in
tolerance t_on
9,10
Reserved
11
Controller enable
12
Drive ready
13
Pulses enabled
Application:
Armature short-circuit protection must only be switched on when the pulses are inhibited.
This signal can be evaluated as one of many conditions when armature short-circuit protection is activated.
14,15 Reserved
AKTSATZ
See function diagram [3650].
Table 9- 19
Description of AKTSATZ (active traversing block/MDI active)
Bit
Meaning
0
Active traversing block, bit 0
1
Active traversing block, bit 1
2
Active traversing block, bit 2
3
Active traversing block, bit 3
4
Active traversing block, bit 4
5
Active traversing block, bit 5
6 ... 14
Reserved
15
MDI active
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
1
No thermal overload in power unit alarm
The temperature of the heat sink in the power unit is
within the permissible range.
0
Thermal overload in power unit alarm
The temperature of the heat sink in the power unit is
outside the permissible range.
If the overtemperature remains, the drive switches
itself off after approx. 20 s.
1
The speed setpoint/actual value is within the
tolerance p2163: The signal is switched on after the
delay specified in p2167 has elapsed.
0
The speed setpoint/actual value is outside the
tolerance.
-
-
1
Controller enable
1
Drive ready
1
Pulses enabled
The pulses for activating the motor are enabled.
0
Pulses inhibited
-
-
Active traversing block (6-bit counter)
1
MDI active
0
MDI not active
9.2 Communication according to PROFIdrive
Remarks
Remarks
Communication
Parameter
BO: r2135.15
BO: r2199.4
-
BO: r0899.8
BO: r0899.7
BO: r0899.11
-
Parameter
BO: r2670.0
BO: r2670.1
BO: r2670.2
BO: r2670.3
BO: r2670.4
BO: r2670.5
BO: r2670.15
553