Siemens Sinamics S110 Function Manual page 341

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Password
The Safety password protects the Safety parameters against unintentional or unauthorized
access.
In commissioning mode for Safety Integrated (p0010 = 95), you cannot change Safety
parameters until you have entered the valid Safety password in p9761 for the drive.
● When Safety Integrated is commissioned for the first time, the following applies:
● In the case of a series commissioning of Safety or in the case of spare part installation,
● Change password for the drive
If you need to change Safety parameters but you do not know the Safety password, proceed
as follows:
1. Resetting the drive unit to factory settings.
2. Recommission the drive unit and drive.
3. Recommission Safety Integrated.
Or contact your regional Siemens office and ask for a readout of the password (complete
drive project must be made available).
Overview of important parameters (see SINAMICS S110 List Manual)
● p9761 SI password input
● p9762 SI password new
● p9763 SI password acknowledgment
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
– Default of p9761 = 0 (SI password entry drive)
In other words:
The Safety password does not need to be set during first commissioning.
the following applies:
– The Safety password is retained on the memory card and in the STARTER project.
– No Safety password is required in the case of spare part installation.
– p0010 = 95 Commissioning mode
– p9761 = Enter "old Safety password".
– p9762 = Enter "new password".
– p9763 = Confirm "new password".
– The new and confirmed Safety password is valid immediately.
Alternatively, you can change the Safety password using the STARTER screen.
8.2 General information about SINAMICS Safety Integrated
Safety Integrated Functions
339