Siemens Sinamics S110 Function Manual page 466

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Safety Integrated Functions
8.9 Acceptance test and acceptance report
3. Test of the SI function "Safe Brake Control (SBC)"
4. Test of the SI function "Safe Stop 2" (SS2)
5. Test of the SI function "Safe Operating Stop" (SOS)
6. Test of the SI function "Safely Limited Speed" (SLS)
7. Test of the SI function "Safe Direction" (SDI)
8. Test of the SI function "Safe Speed Monitor" (SSM)
C) Functional testing of forced dormant error detection
Testing the forced dormant error detection of the safety functions for each control type.
1. Test of the forced dormant error detection of the safety function on the drive
464
– Required when using Basic and/or Extended Functions
– You do not need to prepare trace recording for this test.
– Only required when used in Extended Functions
– This test is also required if you are not explicitly using SS2 but just one function for
which STOP C occurs as an error response.
Alternatively, you can also carry out the quantitative test using STOP C yourself, if you
use the table from section Acceptance test for Safe Stop 2 (Extended Functions)
(Page 486).
– Trace recording is required
– Only required when used in Extended Functions
– This test is also required if you are not explicitly using SOS, but just one function for
which STOP D or STOP E occurs as an error response.
Alternatively, you can also carry out the qualitative test using STOP C, STOP D or
STOP E yourself, if you use the table from section Acceptance test for Safe Operating
Stop (SOS) (Page 489).
– Trace recording is required
– Only required when used in Extended Functions
– A trace recording is required for each SLS limit
– Only required when used in Extended Functions
– Trace recordings are required for each stop response used
– Only required when used in Extended Functions
– Trace recording is required
– If you are using Basic Functions, you need to activate and then deactivate STO once
again.
– If you are using Extended Functions, you need to carry out a test stop.