F-Di/F-Do Configuration - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

8.7.3.5

F-DI/F-DO configuration

Inputs screen F-DI
Figure 8-29
Inputs screen
● NC/NO contact (p10040)
● LED symbol in the F-DI screen
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Terminal property F-DI 0-2 (p10040.0 = F-DI 0, ... p10040.2 = F-DI 2): Configure only the
property of the second (lower) digital input. Always connect an NC contact to digital input
1 (upper). Digital input 2 can be configured as NO contact.
The LED symbol downstream of the AND element indicates the logical state (inactive:
gray, active: green, discrepancy error: red).
Safety Integrated Functions
8.7 Commissioning