Communication; Fieldbus Configuration - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Communication

9.1

Fieldbus configuration

Fieldbus configuration
As an alternative, you can switch the fieldbus interface to communication via PROFIBUS or
USS protocol.
Note
The PROFIdrive configuration is not active if you have set USS.
Configuration in STARTER
To configure the fieldbus interface in STARTER, proceed as follows:
1. Select STARTER → Communication → Fieldbus.
Figure 9-1
Fieldbus protocol selection
2. Select one of the following options from this dialog:
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
– No protocol
– USS
Then define the basic settings for the USS interface in this dialog. Next, select
STARTER → <drive> → Communication to define the data for the send/receive
directions, etc. (see "Communication using USS" (Page 640)).
– PROFIBUS
Click Telegram configuration to define the length of the PZD telegram and specify
additional data for send/receive directions, etc. (see "Communication via PROFIBUS
DP" (Page 589)).
9
521