5.1.3

Sensor Module Cabinet SMC10 / SMC20

Table 5- 3
Sensor Module Cabinet 10 / 20 (SMC10 / SMC20) – description of the LEDs
LED
Color
RDY
-
off
READY
Green
Continuous
Orange
Continuous
Red
Continuous
Green/re
0.5 Hz
d
flashing
light
2 Hz
flashing
light
Green/or
Flashing
ange
light
or
Red/oran
ge
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Status
Electronics power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is driven irrespective of the corresponding messages
being reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON
Component recognition via LED is activated (p0144)
Note:
Both options depend on the LED status when component
recognition is activated via p0144 = 1.
Description, cause
Diagnostics
5.1 Diagnostics via LEDs
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON