Diagnostics
5.2 Diagnostics via STARTER
Starting/stopping the measuring function
With the corresponding measuring function parameter settings (e.g. offset), the motor can
"drift" and travel to its end stop.
The movement of the drive is not monitored while the measuring function is active.
To start the measuring function:
1. Ensure that the prerequisites for starting the measuring function are fulfilled.
2. Select the drive (as control panel).
3. Set the measuring function.
4. Load the settings to the target system ("Download parameterization" button).
5. Start the ramp-function generator ("Start measuring function" button)
To stop the measuring function:
● "Stop measuring function" button
Parameterization
The "Measurement function" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool.
Figure 5-8
100
CAUTION
– Activate the control panel.
Drive_1 → Commissioning → Control panel
– Switch on the drive.
Control board → Issue enable signals → Switch on
e.g. current controller setpoint change
STARTER icon for "Measuring function"