Nikon Eclipse TI-TIRF-E Setup Manual page 275

Illuminator unit/motorized illuminator unit/photo activation illuminator unit, beamsplitter 50/50
Table of Contents

Advertisement

Laser safety kit
Safety label (6)
Protection plate
(for nosepiece)
Analyzer port
Safety label (8)
(Both sides)
Figure 1.4-7
(6) IEC caution label - Class 3B area
CAUTION – CLASS 3B
LASER RADIATION WHEN OPEN
AVOID EXPOSURE TO THE BEAM
VORSICHT – LASERSTRAHLUNG
KLASSE 3B,
WENN ABDECKUNG GEÖFFNET
NICHT DEM STRAHL AUSSETZEN
(8) IEC aperture label 2
AVOID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
Figure 1.4-8
Chapter 1 System Configurations and Part Names
1.4 Name of Each Part
Filter slider cover
Dia pillar illuminator
Filter cube port
cover retaining plate
ON
OFF
6V30W
12V100 W
MAX.
Safety label (6)
(Both sides)
The laser safety kit is supplied with all laser
products mounted onto a Ti microscope.
Labels affixed to each laser product include a
name label and other types of necessary labels,
both of which are not shown here.
The laser safety kit is composed of the filter slider
cover, protection plate for nosepiece, filter cube
port cover retaining plate, and safety labels, "(6)
IEC caution label – Class 3B areas" and "(8) IEC
aperture label". Before using the microscope,
CHECK that each part of the laser safety kit is
correctly attached. (See the figure below.)
Filter slider cover
The filter slider cover is a component designed for
preventing unintended exposure of eyes or skin at
the slider port to laser light emitted to the dia-pillar
illuminator. To attach it to the Ti microscope, lay it
over the dia-pillar illuminator and secure it with the
screws and nuts provided with the kit.
Filter cube port cover retaining plate
The filter cube port cover retaining plate is a
component designed for preventing accidental
leakage of laser light upon occurrence of
unintended opening of the filter cube port cover.
Attach it to the side of the epi-fl filter turret's lower
plate using the screws provided with the kit.
Safety labels
The label (6) affixed to the upper left side (when
viewed from the Binocular eyepiece tube) of the dia
pillar indicates that the laser light may come out
from the aperture when the lamphouse is removed
for replacement of the lamp inside.
Another labels (6) on both sides of the microscope
base indicates that the laser light may come out
from the aperture while attaching the epi-fl filter
turret or the nosepiece to the microscope.
The labels (8) on both sides of the microscope
base indicates that the laser light may come out of
the analyzer port.
2-17