Alcatel-Lucent 7750 SR OS Interface Configuration Manual page 214

7750 sr series
Hide thumbs Also See for 7750 SR OS:
Table of Contents

Advertisement

Configuring Ports
Configuring a Channelized DS1 Card
7750 SR-c12 and 7750 SR-c4 support channelized DS-1 cards. The channelization is as follows:
To make sure you have a channel-capable MDA or CMA, verify the MDA-type you are
configuring by entering a show mda slot-id command.
In the following example, MDA 7 shows a channelized DS1 CMA.
A:7710-3>config# show mda
===============================================================================
MDA Summary
===============================================================================
Slot
Mda
-------------------------------------------------------------------------------
1
1
3
5
6
7
8
===============================================================================
Page 214
The published switchover times for bundle protection groups on the router are dependent
on the far end being able to recover from cell loss within that time. To ensure this, the
following recommendations are given:
→ The BPGrp link activation timer should be configured to a value small enough to
allow a quick recovery from any IMA failure occurring during the switchover. A
recommended value is 1 second.
→ The ADM that terminates APS should support standard APS switchover time
requirements.
→ The far end IMA/MLPPP links must be able to tolerate cell loss during APS
switchover without bringing links down. This includes, for example, a combination of
link activation/deactivation and appropriate configuration of TDM/SONET debounce
timers.
→ Because of the temporary cell loss during the APS switchover, the far end IMA/
MLPPP will experience a misalignment between individual links within an IMA/
MLPPP group. The far end IMA/MLPPP group must support fast-realignment of links
without having to bring the links down. The router synchronizes the IMA/MLPPP
streams the far end receives between switchovers in an effort to cause the least amount
of misalignment.
→ To increase the BPGrp robustness, it is recommended to provision more IMA/MLPPP
links than is required and set the minimum links and max bandwidth parameters to the
number of required links. This type of configuration is required on the far end as well.
N*DS0 in DS1 port.{1..24}
N*DS0 in E1 port.{1..32}
Provisioned
Mda-type
m60-10/100eth-tx
m4-atmoc12/3-sfp
c8-10/100eth-tx
c1-1gb-sfp
c8-chds1
c4-ds3
Equipped
Mda-type
m60-10/100eth-tx
m4-atmoc12/3-sfp
c8-10/100eth-tx
c1-1gb-sfp
c8-chds1
c4-ds3
7750 SR OS Interface Configuration Guide
Admin
Operational
State
State
up
up
up
up
up
up
up
up
up
up
up
up

Advertisement