Configuring Cpipe Port Parameters
Before a Cpipe service can be provisioned, the following entities must be configured.
Configuring a DS1 Port
The following displays an example of a DS1 port configured for CES.
A:sim216#
===============================================================================
TDM DS1 Interface
===============================================================================
Description
Interface
Type
Admin Status
Physical Link
Signal Mode
Last State Change
Loopback
Remote Loop respond: false
Load-balance-algo
BERT Duration
BERT Synched
BERT Errors
BERT Total Bits
Cfg Alarm
Alarm Status
===============================================================================
A:sim216#
Configuring a Channel Group
The following displays an example of a DS1 channel group configured for CES.
A:sim216#
===============================================================================
TDM DS0 Chan Group
===============================================================================
Description
Interface
TimeSlots
Speed
Admin Status
Last State Change
Configured mode
Admin MTU
7750 SR OS Interface Configuration Guide
Configuring a DS1 Port on page 187
Configuring a Channel Group on page 187
show port 1/5/1.1.3.1
: DS1
: 1/5/1.1.3,1
: ds1
: up
: yes
: none
: 10/31/2006 14:23:12
: none
: default
: N/A
: 00h00m00s
: 0
: 0
: ais los
:
show port 1/5/1.1.3.1
: DS0GRP
: 1/5/1.1.3.1
: 1-12
: 64
: up
: 10/31/2006 14:23:12
: access
: 4112
Interface Configuration
Framing
: esf
Oper Status
: up
Clock Source
: loop-timed
Channel IfIndex
: 580943939
Invert Data
: false
In Remote Loop
: false
Egr. Sched. Pol
: n/a
BERT Pattern
: none
Err Insertion Rate
: 0
BERT Status
: idle
CRC
: 16
Oper Status
: up
Chan-Grp IfIndex
: 580943940
Encap Type
: cem
Oper MTU
: 4112