Basic Configuration

Basic Configuration
The most basic configuration must have the following:
The following example displays some card configurations:
ALA-A>config# info
#------------------------------------------
# Card Configuration
#------------------------------------------
card 1
exit
card 2
exit
card 3
exit
card 8
Page 146
Identify chassis slot.
Specify line card type (must be an allowed card type).
Specify MCM slot for 7750 SR-c4 and SR-c12 only (not required for CMA)
Specify MCM type 7750 SR-c4 and SR-c12 only (must be an allowed MCM type)
Identify MDA slot.
Specify MDA type (must be an allowed MDA type).
Identify specific port to configure.
card-type iom-20g
mda 1
mda-type m60-10/100eth-tx
exit
mda 2
mda-type m60-10/100eth-tx
exit
card-type iom-20g
mda 1
mda-type m10-1gb-sfp
exit
mda 2
mda-type m10-1gb-sfp
exit
card-type iom-20g
mda 1
mda-type m12-ds3
exit
mda 2
mda-type m12-ds3
exit
card-type iom-20g
mda 1
mda-type m8-oc12/3-sfp
exit
mda 2
mda-type m16-oc12/3-sfp