Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 462

Analog control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

CH1 Celsius/Fahrenheit display monitor
A status of Celsius/Fahrenheit display in operation is stored.
Monitor value
0
1
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Celsius/Fahrenheit display monitor
CH Celsius/Fahrenheit display monitor (In FX2N allocation
mode function)
Celsius (0) is displayed for a conversion disabled channel regardless of the 'CH1 Celsius/Fahrenheit display
setting' (Un\G547).
CH1 NowSetting user range base input type monitor
This area is used to check the input type of user range setting that is registered in offset/gain setting mode.
Monitor value
1
2
3
4
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH NowSetting user range base input type monitor
CH1 NowSetting user range base input type monitor [FX2N allocation mode]
This area is used to check the input type of user range setting that is registered in offset/gain setting mode in FX2N allocation
mode.
Monitor value
1
2
4
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH NowSetting user range base input type monitor (In FX2N
allocation mode function)
APPX
460
Appendix 12 Buffer Memory Areas
Setting content
Celsius
Fahrenheit
CH1
CH2
CH3
452
652
852
1051
1052
1053
Setting content
Current
Voltage
Resistance temperature detector
Thermocouple
CH1
CH2
CH3
453
653
853
Setting content
Current
Voltage
Thermocouple
CH1
CH2
CH3
1061
1062
1063
CH4
CH5
CH6
1052
1252
1452
1054
1055
1056
CH4
CH5
CH6
1053
1253
1453
CH4
CH5
CH6
1064
1065
1066
CH7
CH8
1652
1852
1057
1058
CH7
CH8
1653
1853
CH7
CH8
1067
1068

Advertisement