Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 425

Analog control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Address
Address
(decimal)
(hexadecimal)
70
46H
71 to 89
47H to 59H
90
5AH
91
5BH
92
5CH
93
5DH
94
5EH
95
5FH
96
60H
97
61H
98
62H
99
63H
100 to 295
64H to 127H
296, 297
128H, 129H
298
12AH
299
12BH
300 to 303
12CH to 12FH
304
130H
305
131H
306 to 399
132H to 18FH
■Un\G400 to Un\G3599
Address
Decimal (hexadecimal)
CH1
CH2
CH3
CH4
400
600
800
1000
(190H)
(258H)
(320H)
(3E8H)
401
601
801
1001
(191H)
(259H)
(321H)
(3E9H)
402
602
802
1002
(192H)
(25AH)
(322H)
(3EAH)
403
603
803
1003
(193H)
(25BH)
(323H)
(3EBH)
404
604
804
1004
(194H)
(25CH)
(324H)
(3ECH)
405
605
805
1005
(195H)
(25DH)
(325H)
(3EDH)
406
606
806
1006
(196H)
(25EH)
(326H)
(3EEH)
407, 408
607, 608
807, 808
1007,
(197H,
(25FH,
(327H,
1008
198H)
260H)
328H)
(3EFH,
3F0H)
409
609
809
1009
(199H)
(261H)
(329H)
(3F1H)
410 to
610 to
810 to
1010 to
419
619
819
1019
(19AH to
(262H to
(32AH to
(3F2H to
1A3H)
26BH)
333H)
3FBH)
420
620
820
1020
(1A4H)
(26CH)
(334H)
(3FCH)
421
621
821
1021
(1A5H)
(26DH)
(335H)
(3FDH)
422
622
822
1022
(1A6H)
(26EH)
(336H)
(3FEH)
Name
Output signals
System area
Level data 0
Level data 1
Level data 2
Level data 3
Level data 4
Level data 5
Level data 6
Level data 7
Level data 8
Level data 9
System area
Mode switching setting
System area
Rate alarm change rate selection
System area
Input signal error/Disconnection detection automatic clear
enable/disable setting
Offset/gain initialization enable code
System area
CH5
CH6
CH7
1200
1400
1600
(4B0H)
(578H)
(640H)
1201
1401
1601
(4B1H)
(579H)
(641H)
1202
1402
1602
(4B2H)
(57AH)
(642H)
1203
1403
1603
(4B3H)
(57BH)
(643H)
1204
1404
1604
(4B4H)
(57CH)
(644H)
1205
1405
1605
(4B5H)
(57DH)
(645H)
1206
1406
1606
(4B6H)
(57EH)
(646H)
1207,
1407,
1607,
1208
1408
1608
(4B7H,
(57FH,
(647H,
4B8H)
580H)
648H)
1209
1409
1609
(4B9H)
(581H)
(649H)
1210 to
1410 to
1610 to
1219
1419
1619
(4BAH
(582H to
(64AH to
to
58BH)
653H)
4C3H)
1220
1420
1620
(4C4H)
(58CH)
(654H)
1221
1421
1621
(4C5H)
(58DH)
(655H)
1222
1422
1622
(4C6H)
(58EH)
(656H)
Default value
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
Name
CH8
1800
CH Digital output value
(708H)
1801
System area
(709H)
1802
CH Digital operation value
(70AH)
1803
System area
(70BH)
1804
CH Maximum value
(70CH)
1805
System area
(70DH)
1806
CH Minimum value
(70EH)
1807,
System area
1808
(70FH,
710H)
1809
CH Logging hold flag
(711H)
1810 to
System area
1819
(712H to
71BH)
1820
CH Conversion status
(71CH)
1821
System area
(71DH)
1822
CH Maximum value reset
(71EH)
completed flag
Appendix 12 Buffer Memory Areas
Data type
Auto refresh
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Setting
Setting
Setting
Setting
Default
Data
Auto
value
type
refresh
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
APPX
A
423

Advertisement

Table of Contents
loading

Table of Contents