Address: decimal (hexadecimal)
CH1
CH2
101 (65H)
102 (66H)
105 to 108 (69H to 6CH)
109 (6DH)
110 (6EH)
111 (6FH)
112 (70H)
115 to 118 (73H to 76H)
119 (77H)
120 (78H)
121 to 123 (79H to 7BH)
124 (7CH)
125 to 129 (7DH to 81H)
130 (82H)
131, 132 (83H, 84H)
133 (85H)
134 to 999 (86H to 3E7H)
1000 (3E8H)
1002 (3EAH)
1001 (3E9H)
1003 (3EBH)
1008 to 1020 (3F0H to 3FCH)
1021 (3FDH)
1022 (3FEH)
1025 to 1030 (401H to 406H)
1031 (407H)
1032 (408H)
1035 to 1080 (40BH to 438H)
1081 (439H)
1082 (43AH)
1085 to 1090 (43DH to 442H)
1091 (443H)
1092 (444H)
1095 to 1099 (447H to 44BH)
1100 (44CH)
1102 (44EH)
1101 (44DH)
1103 (44FH)
1108 to 1119 (454H to 45FH)
1120 (460H)
1122 (462H)
1121 (461H)
1123 (463H)
1128 to 1140 (468H to 474H)
1141 (475H)
1142 (476H)
1145 to 1150 (479H to 47EH)
1151 (47FH)
1152 (480H)
1155 to 1160 (483H to 488H)
1161 (489H)
1162 (48AH)
1165 to 1170 (48DH to 492H)
APPX
118
Appendix 4 Buffer Memory Areas
CH3
CH4
103 (67H)
104 (68H)
113 (71H)
114 (72H)
1004 (3ECH)
1006 (3EEH)
1005 (3EDH)
1007 (3EFH)
1023 (3FFH)
1024 (400H)
1033 (409H)
1034 (40AH)
1083 (43BH)
1084 (43CH)
1093 (445H)
1094 (446H)
1104 (450H)
1106 (452H)
1105 (451H)
1107 (453H)
1124 (464H)
1126 (466H)
1125 (465H)
1127 (467H)
1143 (477H)
1144 (478H)
1153 (481H)
1154 (482H)
1163 (48BH)
1164 (48CH)
Name
Default
value
CH Minimum value
0
System area
Minimum value reset request
0000H
Minimum value reset
0000H
completed flag
CH Maximum value
0
System area
Maximum value reset request
0000H
Maximum value reset
0000H
completed flag
System area
A/D conversion completed
0000H
flag
System area
Rate alarm change rate
0001H
selection
System area
Input signal error detect
0001H
automatic clear enable/
disable setting
System area
*1
CH Digital output value
System area
System area
CH A/D conversion status
0000H
System area
CH Range setting monitor
0
System area
CH Averaging process
0000H
specification
System area
CH Scaling enable/disable
0001H
setting
System area
CH Scaling upper limit
0
value (L)
CH Scaling upper limit
value (H)
System area
CH Scaling lower limit
0
value (L)
CH Scaling lower limit
value (H)
System area
CH Digital clipping enable/
0001H
disable setting
System area
CH Input signal error
0001H
detection setting
System area
CH Input signal error
20
detection lower limit setting
value
System area
Data
Auto
type
refresh
Monitor
Control
Monitor
Monitor
Control
Monitor
Monitor
Setting
Setting
Monitor
Monitor
Monitor
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting