Address
Decimal (hexadecimal)
CH1
CH2
9010 (2332H)
9012 (2334H)
9011 (2333H)
9013 (2335H)
9018 to 9029 (233AH to 2345H)
9030 (2346H)
9032 (2348H)
9031 (2347H)
9033 (2349H)
9038 to 9049 (234EH to 2359H)
9050 (235AH)
9052 (235CH)
9051 (235BH)
9053 (235DH)
9058 to 9069 (2362H to 236DH)
9070 (236EH)
9072 (2370H)
9071 (236FH)
9073 (2371H)
9078 to 9089 (2376H to 2381H)
9090 (2382H)
9092 (2384H)
9091 (2383H)
9093 (2385H)
9098 to 9109 (238AH to 2395H)
9110 (2396H)
9112 (2398H)
9111 (2397H)
9113 (2399H)
9118 to 9130 (239EH to 23AAH)
9131 (23ABH)
9132 (23ACH)
9135 to 9139 (23AFH to 23B3H)
9140 (23B4H)
9142 (23B6H)
9141 (23B5H)
9143 (23B7H)
9148 to 9160 (23BCH to 23C8H)
9161 (23C9H)
9162 (23CAH)
9165 to 9170 (23CDH to 23D2H)
9171 (23D3H)
9172 (23D4H)
9175 to 9179 (23D7H to 23DBH)
9180 (23DCH)
9182 (23DEH)
9181 (23DDH)
9183 (23DFH)
9188 to 9199 (23E4H to 23EFH)
9200 (23F0H)
9202 (23F2H)
9201 (23F1H)
9203 (23F3H)
9208 to 9220 (23F8H to 2404H)
9221 (2405H)
9222 (2406H)
9225 to 9230 (2409H to 240EH)
APPX
290
Appendix 8 Buffer Memory Areas
CH3
CH4
9014 (2336H)
9016 (2338H)
9015 (2337H)
9017 (2339H)
9034 (234AH)
9036 (234CH)
9035 (234BH)
9037 (234DH)
9054 (235EH)
9056 (2360H)
9055 (235FH)
9057 (2361H)
9074 (2372H)
9076 (2374H)
9075 (2373H)
9077 (2375H)
9094 (2386H)
9096 (2388H)
9095 (2387H)
9097 (2389H)
9114 (239AH)
9116 (239CH)
9115 (239BH)
9117 (239DH)
9133 (23ADH)
9134 (23AEH)
9144 (23B8H)
9146 (23BAH)
9145 (23B9H)
9147 (23BBH)
9163 (23CBH)
9164 (23CCH)
9173 (23D5H)
9174 (23D6H)
9184 (23E0H)
9186 (23E2H)
9185 (23E1H)
9187 (23E3H)
9204 (23F4H)
9206 (23F6H)
9205 (23F5H)
9207 (23F7H)
9223 (2407H)
9224 (2408H)
Name
CH Wave output conversion cycle
monitor (L)
CH Wave output conversion cycle
monitor (H)
System area
CH Wave pattern output count
monitor
System area
System area
CH Wave output current address
monitor (L)
CH Wave output current address
monitor (H)
System area
CH Wave output current digital
value monitor
System area
System area
CH Wave output digital value
outside the range Address monitor
(L)
CH Wave output digital value
outside the range Address monitor
(H)
System area
CH Wave output warning Address
monitor (L)
CH Wave output warning Address
monitor (H)
System area
CH Wave output start/stop request
System area
CH Wave output step action
movement amount
System area
System area
CH Output setting during wave
output stop
System area
CH Output value during wave
output stop
System area
CH Wave pattern start address
setting (L)
CH Wave pattern start address
setting (H)
System area
CH Wave pattern data points
setting (L)
CH Wave pattern data points
setting (H)
System area
CH Wave pattern output repetition
setting
System area
Default
Data
Auto
value
type
refresh
0
Monitor
Monitor
0
Monitor
0
Monitor
Monitor
0
Monitor
0
Monitor
Monitor
0
Monitor
Monitor
0
Control
0
Control
1
Setting
0
Setting
10000
Setting
Setting
0
Setting
Setting
1
Setting

Advertisement