[Pausing the wave output]
• To pause the wave output, set 'CH1 Wave output start/stop request' (Un\G462) to Wave output pause request (2). The
wave output pauses by changing from Wave output start request (1) to Wave output pause stop request (2). In addition,
Wave output paused (2) is stored in 'CH1 Wave output status monitor' (Un\G401).
• To restart the wave output, change 'CH1 Wave output start/stop request' (Un\G462) from Wave output pause request (2) to
Wave output start request (1). This restarts the wave output from the wave data generated when the pause occurred.
• If 'CH1 Wave output start/stop request' (Un\G462) is set to Wave output temporary stop request (2) while the wave output is
at a stop, the following will be output depending on HOLD/CLEAR setting.
Previous Value: Outputs the digital value of the wave pattern start address.
Setting value: Outputs the HOLD setting value.
CLEAR: Outputs the offset value.
CPU module status
CH1 D/A conversion
enable/disable setting (Un\G500)
CH1 Output enable/disable flag
(Un\G70, b1)
CH1 Wave output start/stop
request (Un\G462)
CH1 Wave output status monitor
(Un\G401)
Wave data
Output value as per the setting of CH1
Output setting during wave output stop (Un\G524)
The wave output stops by setting 'CH1 Wave output start/stop request' (Un\G462) to Wave output pause request (2) during wave output.
The wave output restarts by setting 'CH1 Wave output start/stop request' (Un\G462) to Wave output start request (1).
The analog output value obtained during the wave output paused state depends on the setting of the analog output HOLD/
CLEAR function. For details, refer to the following.
Page 187 In the wave output mode
D/A conversion enable (0)
OFF
Wave output
Wave output stop request (0)
start request (1)
Wave output
Wave output stopped (0)
in progress (1)
Analog output
Offset value
RUN
ON
Wave output
Wave output start request (1)
pause request (2)
Wave output paused (2)
Wave output stopped (0)
Wave output
in progress
(1)