Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 305

Analog control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Interrupt factor generation setting [n]
Set an interrupt request for when the same interrupt factor occurs during the interrupt factor detection.
Setting value
0
1
• When 'Interrupt factor generation setting [n]' (Un\G200 to Un\G215) is Interrupt resend request (0) and the same interrupt
factor occurs during the interrupt factor detection, an interrupt request is sent to the CPU module again.
• When 'Interrupt factor generation setting [n]' (Un\G200 to Un\G215) is No interrupt resend request (1) and the same
interrupt factor occurs during the interrupt factor detection, an interrupt request is not sent to the CPU module.
If a value other than the above is set, an interrupt factor generation setting range error (error code: 180H) occurs.
"n" and  indicate an interrupt setting number. (n = 1 to 16,  = 0 to F)
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
Interrupt factor generation setting
[n]
Interrupt factor generation setting
[n] (in FX3 allocation mode)
■Enabling the setting
Turn on and off 'Operating condition setting request' (Un\G70, b9) to enable the setting.
■Default value
The default value is Interrupt resend request (0) for all buffer memory areas.
Condition target setting [n]
Set an interrupt factor to be detected.
Setting value
0
1
2
3
4
If a value other than the above is set, a condition target setting range error (error code: 181H) occurs.
Turning off and on 'Error flag', 'Alarm output flag' and 'Disconnection detection flag' set in 'Condition target setting [n]'
(Un\G232 to Un\G247) or turning on and off 'External power supply READY flag' set in 'Condition target setting [n]' (Un\G232
to Un\G247) send an interrupt request for the CPU module.
"n" and  indicate an interrupt setting number. (n = 1 to 16,  = 0 to F)
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
Condition target setting [n]
Condition target setting [n] (in
FX3 allocation mode function)
■Enabling the setting
Turn on and off 'Operating condition setting request' (Un\G70, b9) to enable the setting.
■Default value
The default value is Disable (0) for all buffer memory areas.
1
2
3
4
5
200
201
202
203
204
4061
4062
4063
4064
4065
1
2
3
4
5
232
233
234
235
236
4081
4082
4083
4084
4085
Setting content
Interrupt resend request
No interrupt resend request
6
7
8
9
10
205
206
207
208
209
4066
4067
4068
4069
4070
Setting content
Disable
Error flag (Un\G69, b15)
Alert output flag
Disconnection detection flag
External power supply READY flag (Un\G69, b7)
6
7
8
9
10
237
238
239
240
241
4086
4087
4088
4089
4090
11
12
13
14
15
210
211
212
213
214
4071
4072
4073
4074
4075
11
12
13
14
15
242
243
244
245
246
4091
4092
4093
4094
4095
APPX
Appendix 8 Buffer Memory Areas
16
215
4076
A
16
247
4096
303

Advertisement

Table of Contents
loading

Table of Contents