Network Synchronization

PTP Ordinary Master Clock For Frequency

The router supports the PTP ordinary clock in master mode. Normally, a IEEE 1588v2 grand
master is used to support many slaves and boundary clocks in the network. In cases where
only a small number of slaves and boundary clocks exist and only frequency is required, a
PTP integrated master clock can greatly reduce hardware and management costs to
implement PTP across the network. It also provides an opportunity to achieve better
performance by placing a master clock closer to the edge of the network, as close to the slave
clocks as possible.
272
Figure 21: Ordinary Slave Clock Operation
1588v2
Grand
Master
Packet
Network
1588v2
Grand
Master
Figure 22
PRC
TDM/SyncE
shows a PTP master clock network configuration.
Figure 22: PTP Master Clock
Network
CPM A
MDA
Central
Clock
1588
MDA
Clock
PTP
Master
Clock
Packet
Network
Basic System Configuration Guide
B
Internal
(Node)
Timing
Reference
OSSG738
PTP Slave
PTP Slave
PTP Slave
OSSG739