Description
If the management Ethernet port on the active CPM goes down, this command allows the active CPM
to be configured to use the management Ethernet port of the standby CPM.
The revert option allows the administrator to control when to revert back to the management Ethernet
port of the primary CPM once it comes up again.
The no form of the command disables redundancy, so that connectivity to the active CPM is lost if its
Ethernet port goes down.
This feature is not supported on the 7750 SR-a, 7750 SR-c and the VSR platforms.
Default
5 seconds
Parameters
seconds — Specifies the duration to wait (in seconds) before reverting back to the primary CPM's
multi-chassis
Syntax
multi-chassis
Context
config>redundancy
Description
This command enables the context to configure multi-chassis parameters.
redundancy
Syntax
redundancy
Context
admin
config
Description
This command enters the context to allow the user to perform redundancy operations.
rollback-sync
Syntax
rollback-sync
Context
admin>redundancy
Description
This command copies the entire set of rollback checkpoint files from the active CPM CF to the inactive
CPM CF.
Default
None.
Basic System Configuration Guide
management Ethernet port.
Values
1 to 300