rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created.
Configuration example
memory-use-alarm rising-threshold 50000000 falling-threshold 45999999
interval 500 rmon-event-type both start-alarm either
memory-use-warn
Syntax
memory-use-warn rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no memory-use-warn
Context
config>system>thresholds
Description
The memory thresholds are based on monitoring MemoryUsed object. This object contains the amount
of memory currently used by the system. The severity level is Alarm.
The absolute sample type method is used.
The no form of this command removes the configured compact flash threshold warning.
374
Values
log — In the case of log, an entry is made in the RMON-MIB log
table for each event occurrence. This does not create an OS logger
entry. The RMON-MIB log table entries can be viewed using the
CLI command.
Values
trap — In the case of trap, a TiMOS logger event is generated.
The TiMOS logger utility then distributes the notification of this
event to its configured log destinations which may be CONSOLE,
telnet session, memory log, cflash file, syslog, or SNMP trap
destinations logs.
Values
both — In the case of both, both a entry in the RMON-MIB
logTable and a TiMOS logger event are generated.
Values
none — In the case of none, no action is taken.
Default
both
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, then a single rising threshold crossing event is generated. If the first
sample is less than or equal to the falling threshold value and startup-alarm is equal to falling
or either, a single falling threshold crossing event is generated.
Values
rising, falling, either
Default
either