start-alarm either rising-event 5 rising-threshold 10000 falling-event 5
falling-threshold 9000 owner "TiMOS CLI"
cflash-cap-alarm
Syntax
cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The
severity level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
interval seconds — Specifies the polling period, in seconds, over which the data is sampled and
362
Values
cf1:, cf1-A:, cf1-B:, cf2:, cf2-A:, cf2-B:, cf3:, cf3-A:, cf3-B:
sampled value is greater than or equal to this threshold, and the value at the last sampling
interval was less than this threshold, a single threshold crossing event will be generated. A
single threshold crossing event will also be generated if the first sample taken is greater than
or equal to this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal to the falling-
threshold value.
The threshold value represents units of 512 bytes.
Values
-2147483648 to 2147483647
Default
0
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal
to this threshold and the associated startup-alarm is equal to falling or either.
After a falling threshold crossing event is generated, another such event will not be generated
until the sampled value rises above this threshold and reaches greater than or equal to the
rising-threshold value.
The threshold value represents units of 512 bytes.
Values
-2147483648 to 2147483647
Default
0
compared with the rising and falling thresholds.
Values