Alcatel-Lucent 7450 Basic System Configuration Manual page 264

Ethernet service switch /service router /extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

Network Synchronization
The ordinary clock master, ordinary clock slave, and boundary clock set their local
parameters as follows:
Table 33: Local Clock Parameters When Profile is set to ieee1588-2008
Parameter
clockIdentity
clockClass
clockAccuracy
offsetScaledLogVariance
If the profile setting for the clock is g8265dot1-2010, the precedence order for the best master
selection algorithm is:
The ordinary clock master, ordinary clock slave, and boundary clock set their local
parameters as follows:
264
clock class
clock accuracy
PTP variance (offsetScaledLogVariance)
priority2
clock identity
steps removed from the grandmaster
Value
Chassis MAC address following the guidelines of 7.5.2.2.2 of
IEEE 1588
13 — local clock configured as ordinary clock master and is
locked to an external reference
14 — local clock configured as ordinary clock master and in
holdover after having been locked to an external source
248 — local clock configured as ordinary clock master and is in
free run or the router is configured as a boundary clock
255 — local clock configured as ordinary clock slave
FE — unknown
FFFF — not computed
clock class
priority
Basic System Configuration Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

77507950

Table of Contents