Alcatel-Lucent 7450 Basic System Configuration Manual page 91

Ethernet service switch /service router /extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

mac
Syntax
mac mac-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]
Context
monitor>filter
Description
This command enables MAC filter monitoring. The statistical information for the specified MAC filter
entry displays at the configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified MAC filter. The subsequent
statistical information listed for each interval is displayed as a delta to the previous display. When the
keyword rate is specified, the "rate per second" for each statistic is displayed instead of the delta.
Monitor commands are similar to show commands but only statistical information displays. Monitor
commands display the selected statistics according to the configured number of times at the interval
specified.
Parameters
mac-filter-id — The MAC filter policy ID.
entry entry-id — Displays information on the specified filter entry ID for the specified filter ID
interval seconds — Configures the interval for each display in seconds.
repeat repeat — Configures how many times the command is repeated.
absolute — When the absolute keyword is specified, the raw statistics are displayed, without
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed
Output
Sample Output
A:ALA-1>monitor>filter# mac 50 entry 10 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for Mac filter 50 entry 10
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0
------------------------------------------------------------------------------
At time t = 3 sec (Mode: Absolute)
Basic System Configuration Guide
Values
1 to 65535
only.
Values
1 to 65535
Default
5 seconds
Values
3 to 60
Default
10
Values
1 to 999
processing. No calculations are performed on the delta or rate statistics.
instead of the delta.
Egr. Matches
: 0
CLI Usage
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

77507950

Table of Contents