CUSTOM A I R C O N D I T I O N I N G
1A-29
Fig. 1 A - 4 7 Refrigeration System Components
- Tempest
14. Position new metal sleeve retainer so that its
flange face will be against the front end of the sleeve.
Tool J 9395 or the sleeve from tool J 9393 may be
used to install the retainer. Press and tap with a
mallet, setting the retainer and sleeve Into place,
until the outer edge of the retainer is recessed ap
proximately 1/32" from the face of the compressor
neck.
15. Re-install the clutch driven plate.
P.O.A. VALVE-REMOVE
AND
REPLACE
A L L (Figs. 1A-46, 47 and 48)
1. Depressurize system.
2. Loosen oil bleed fitting.
3. Loosen equalizer fitting.
4. Loosen inlet and outlet fittings.
5. Remove valve from bracket.
NOTE:
If valve is not immediately replaced, cap
openings to prevent entry of dirt and moisture.
6. Replace by reversing above procedure using
new O-ring seals coated with compressor oil.
7. Evacuate and charge system.
Compressor belt tension
specifications
are as
follows:
New
Old
A L L
140-145 lbs.
100-105 lbs.
EXPANSION
VALVE
AND
SEALS-REMOVE
AND
REPLACE
(Figs.
IA-46, JA-47 and
1A-48)
1. Depressurize system.
2. Remove thermo bulb from sealer at evaporator
outlet.
3. Disconnect equalizer line at P.O.A. valve.
4. Remove inlet and outlet fittings of valve.
NOTE:
On some models it may be necessary to
loosen and tip the compressor
to gain access
to
these fittings.
5. If valve is not immediately replaced cap open
ings to prevent entry of dirt and moisture.