16
18476
17
18A559
18
19
18A318
20
Function Selector Switch Vacuum Connector
Port No. Hose Color
1
White
2
Red
3
Blue
4
Yellow
5
Black
6
Function Selector Switch Vacuum Application Chart
Switch Port Color
1
White
2
Red
3
Blue
4
Yellow
5
Black Vacuum source
V=Vacuum
NV=No Vacuum
Inspection and Verification
1. Verify the customer's concern by operating the climate control system to duplicate the condition.
Heater core
Panel/floor door (full vacuum position)
Floor airflow
Vacuum control motor—floor/panel door
Panel vent airflow
Function
Air inlet door
Panel/floor door
Panel/floor door
Panel/defrost door
Vacuum source
Not used
Function
MAX A/C A/C Vent OFF Floor FLR/ DEF Defrost
Recirc/Fresh
V
Floor
NV
Panel/floor
NV
Panel/defrost
V
V
Function Selector Switch Position
NV
NV
V
NV
NV
NV
V
V
NV
NV
V
V
V
V
NV
NV
V
V
V
V
NV
NV
NV
NV
V
NV
NV
NV
V
V