Adjustment or repair cannot be made to the evaporator core orifice assembly. A new evaporator
core orifice must be installed as a unit.
Suction Accumulator
Item Part Number
1
19E561
2
—
3
19D701
4
—
5
—
6
—
7
—
8
—
9
—
10
—
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning
system except when there is physical evidence of contamination from a failed A/C compressor or
damage to the suction accumulator.
In addition to the preceding condition, a new suction accumulator should be installed if one of the
following conditions exist:
The suction accumulator is perforated.
The refrigerant system has been opened to the atmosphere for a period of time longer than
required to make a minor repair.
There is evidence of moisture in the system such as internal corrosion of metal refrigerant lines
or the refrigerant oil is thick and dark.
Description
A/C cycling switch
O-ring seal (part of 19C836)
Low pressure service gauge port valve
Inlet from A/C evaporator core (part of 19C836)
Outlet to A/C compressor (part of 19C836)
Anti-siphon hole (part of 19C836)
Desiccant bag (part of 19C836)
Oil return orifice filter (part of 19C836)
Vapor return tube (part of 19C836)
Suction accumulator dome (part of 19C836)