Ford 2003 Mustang Workshop Manual page 3206

Hide thumbs Also See for 2003 Mustang:
Table of Contents

Advertisement

SECTION 412-03: Air Conditioning
REMOVAL AND INSTALLATION
Suction Accumulator
Material
Item
PAG Refrigerant Compressor
Oil (R-134a Systems)
F7AZ-19589-DA (Motorcraft YN-
12-C)
Removal and Installation
1. Recover the refrigerant. For additional information, refer to
2. Disconnect the A/C cycling switch electrical connector.
3. Remove the cycling switch.
4. Disconnect the suction line spring lock coupling.
Discard the O-ring seals.
Specification
WSH-M1C231-
B