8. If the draw is found to be excessive, pull fuses from the battery/central junction box one at a
time and note the current drop. Do not reinstall the fuses until you are finished testing.
9. Check the wiring schematic in the wiring diagram for any circuits that run from the battery
without passing through the battery/central junction box. Disconnect these circuits if the draw is
still excessive.
Battery—Electronic Drains Which Shut Off When the Battery Cable is Disconnected
1. Repeat the steps of the battery drain testing.
2. Make sure all doors are closed and accessories are off. Without starting the engine, turn the
ignition switch to RUN for a moment and then OFF. Wait a few minutes for the illuminated entry
lamps to turn off if equipped.
3. Connect the ammeter and read the amperage draw.
The current reading (current drain) should be less than 50 mA (0.05 amp). If the current drain exceeds
50 mA (0.05 amp) after a few minutes, and if this drain did not show in previous tests, the drain is most
likely caused by an inoperative electronic component. As in previous tests, remove the fuses from the
battery/central junction box one at a time to locate the problem circuit.
Generator On-Vehicle Tests
CAUTION: To prevent damage to the generator, do not make jumper wire connections
except as directed.
CAUTION: Do not allow any metal object to come in contact with the housing and the
internal diode cooling fins with key on or off. A short circuit will result and burn out the diodes.
NOTE: Battery posts and cable clamps must be clean and tight for accurate meter indications.
NOTE: Refer to the Battery Tester Procedure Manual for complete directions for testing the charging
system.
1. Turn off all lamps and electrical components.
2. Place the vehicle in transmission range NEUTRAL and apply the parking brake.
3. Carry out the Load Test and No-Load Test according to the following component tests:
Generator On-Vehicle Tests—Load Test
1. Switch the battery tester to the ammeter function.
2. Connect the positive and negative leads of the battery tester to the corresponding battery
terminals.