9. Remove the bolts and the A/C compressor.
10. To install, reverse the removal procedure.
Install new O-ring seals lubricated in clean PAG oil.
If filtering of the refrigerant system is not to be performed, lubricate the refrigerant system
with the correct amount of clean PAG oil. For additional information, refer to
00
.
11. If filtering of the air conditioning system is not to be performed, evacuate, leak test and charge
the refrigerant system. For additional information, refer to
Section 412-00
.
Section 412-