Kyocera TASKalfa 620 Service Manual page 376

Hide thumbs Also See for TASKalfa 620:
Table of Contents

Advertisement

2KN/2KP
Connector
Pin No.
YC6
1
Connected
2
to the con-
3
veying unit
4
5
6
7
8
9
10
11
12
13
14
15
16
YC7
1
Connected
2
to the high
3
voltage
4
PWB
5
6
7
8
9
10
11
12
YC8
1
Connected
2
to the drum
heater PWB
YC9
1
Connected
2
to the DC
3
power
4
source PWB
5
2-3-24
Signal
I/O
DUP FAN REM
O
R24V
O
GND
-
FEED SHIFT
O
FAN
TRF -CNT
O
R24V
O
TRF +CNT
O
DLP MOT GAIN
O
TRF INV
O
DLP MOT CW
O
TRF REM
O
R24V
O
GND
-
FS SOL PUL
O
R24V
O
FS SOL RTN
O
PTC ALM
I
PTC REM
O
DLP PLS
O
DLP CONT
O
DLP AC REM
O
DLP DC REM
O
G CONT
O
MC ALM
I
MC REM
O
GND
-
R24V
O
DLP AC CNT
O
R24V
O
DRUM HEAT
I
REM
24V
I
GND
-
R24V
I
S5V
I
GND
-
Voltage
0/24 V DC
Duplex fan motor: On/off
24 V DC
24 V DC power output
-
Ground
0/24 V DC
Feedshift fan motor: On/off
Analog
Transfer bias minus output control voltage
24 V DC
24 V DC power output
Analog
Transfer bias plus output control voltage
0/5 V DC
Deveoping motor gain signal
0/24 V DC
Transfer bias plus/minus switching signal
0/5 V DC
Deveoping motor CW signal
0/24 V DC
Transfer high voltage: On/off
24 V DC
24 V DC power output
-
Ground
0/24 V DC
Feedshift solenoid (activate): On/off
24 V DC
24 V DC power output
0/24 V DC
Feedshift solenoid (return): On/off
0/5 V DC
Pre transfer charger alarm signal
0/24 V DC
Pre transfer charger: On/off
0/24 V DC (pulse) Developing bias AC pulse signal
Analog
Developing bias DC control voltage
0/24 V DC
Developing bias AC: On/off
0/24 V DC
Developing bias DC: On/off
Analog
Grid control voltage
0/5 V DC
Main charger alarm signal
0/24 V DC
Main charger: On/off
-
Ground
24 V DC
24 V DC power output
Analog
Developing bias AC control voltage
24 V DC
24 V DC power output
0/24 V DC
Drum heater: On/off
24 V DC
24 V DC power input
-
Ground
24 V DC
24 V DC power input
5 V DC
5 V DC power input
-
Ground
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 820

Table of Contents