(2) Detaching and refitting the cleaning blade
Follow the procedure below to replace the cleaning blade.
Procedure
1. Remove the cleaning unit (see page 1-5-
54).
2. Release two claws and then remove the
upper cleaning cover from the cleaning unit.
3. Remove two screws and then remove the
cleaning blade from the cleaning unit.
4. Replace the cleaning blade.
* When attaching the cleaning blade, adjust
two projections.
5. Refit the upper cleaning cover to the clean-
ing unit.
6. Refit the cleaning unit.
Upper cleaning cover
Claw
Cleaning unit
Figure 1-5-114
Cleaning unit
Cleaning blade
Figure 1-5-115
Projection
Cleaning blade
Cleaning blade
Figure 1-5-116
2KN/2KP
Claw
Projection
1-5-55