(4) Detaching and refitting the cleaning felt
Follow the procedure below to replace the cleaning felt.
Procedure
1. Remove the fuser unit (see page 1-5-58).
2. Remove rear pin and front screw, and then
remove the upper fuser cover.
3. Remove four screws and then remove the
upper fuser frame.
4. Remove the screw and then remove the
fuser cleaning cover from the upper fuser
frame.
Upper fuser cover
Screw
Figure 1-5-128
Upper fuser frame
Screws
Figure 1-5-129
Upper fuser frame
Figure 1-5-130
2KN/2KP
Pin
Fuser unit
Screws
Fuser unit
Fuser cleaning cover
1-5-61