2KN/2KP
Code
C6000
Fuser heater lamp break
• The fuser temperature does not
increase for 40 s after the fuser heat-
ers have been turned on for warming
up.
• The fuser temperature remains below
°
50
C/122
after the fuser heaters have been
turned on during stabilization.
C6020
Fuser thermistor high-temperature
detection error
• The fuser temperature exceeds 235
°
°
C/455
F for 10 s.
C6030
Fuser thermistor break error
• The fuser temperature remains at
lower then 0
ously when the fuser heater is on.
C6050
Fuser thermistor abnormal tempera-
ture detection
• During copying, the temperature at the
heat roller lower than 120
detected continuously for 5 s.
1-4-40
Contents
°
F for 10 s continuously
°
°
C/32
F for 30 s continu-
°
°
C/248
F is
Causes
Check procedures/corrective measures
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and S.
repair it.
Defective fuser
Replace the fuser thermostat 1 or 2 (see
thermostat 1 or 2.
page 1-5-63).
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor L, M and S. If any problem is found,
heater L, M or S.
repair it.
Broken fuser
Check for continuity. If none, replace the
heater L, M and S
fuser heater L, M and S (see page 1-5-66).
wire.
Defective engine
Replace the engine PWB.
PWB.
Defective AC
Replace the AC power source PWB.
power source
PWB.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and S.
repair it.
Defective fuser
Replace the fuser thermistor M and S (see
thermistor M and
page 1-5-63).
S.
Defective engine
Replace the engine PWB.
PWB.
Defective engine
Replace the engine PWB.
PWB.
Defective AC
Replace the AC power source PWB.
power source
PWB.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and S.
repair it.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and S.
repair it.
Operation on fuser
Check for continuity. If none, replace the
thermostat 1 or 2.
fuser thermostat 1 or 2.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor L, M and S. If any problem is found,
heater L, M or S.
repair it.
Broken fuser
Check for continuity. If none, replace the
heater L, M and S
fuser heater L, M and S (see page 1-5-66).
wire.
Defective engine
Replace the engine PWB.
PWB.
Defective AC
Replace the AC power source PWB.
power source
PWB.
Remarks