Section
Jam code
Duplex
63
section
64
65
66
DP section
70
71
72
73
74
* Description in ( ) is written for the specified time of less then A4/11" x 8
Description
Misfeed in duplex registra-
tion section
Misfeed in duplex convey-
ing section 1
Misfeed in duplex convey-
ing section 2
Misfeed in duplex convey-
ing section 3
No original feed
An original jam in the orig-
inal feed/conveying sec-
tion 1
An original jam in the orig-
inal feed/conveying sec-
tion 2
An original jam in the orig-
inal conveying section
An original jam remaining
after retries
Switchback exit switch (SBESW) does not turn off within spec-
ified time (2000 ms for 82 cpm/2573 ms for 62 cpm) of its turn-
ing on.
Duplex feed switch (DUPFSW) does not turn on within speci-
fied time (1136 ms for 82 cpm/1462 ms for 62 cpm) of exit
switch (ESW) turning on.
Switchback exit switch (SBESW) does not turn on within spec-
ified time (864 ms for 82 cpm/1111 ms for 62 cpm) of duplex
feed switch (DUPFSW) turning on.
Duplex conveying switch 1 (DUPCSW1) does not turn on
within specified time (750 ms for 82 cpm/1000 ms for 62 cpm)
of duplex feed switch (DUPFSW) turning on.
Duplex conveying switch 1 (DUPCSW1) does not turn off
within specified time (750 ms for 82 cpm/1000 ms for 62 cpm)
of duplex feed switch (DUPFSW) turning off.
Duplex conveying switch 2 (DUPCSW2) does not turn on
within specified time (750 ms for 82 cpm/1000 ms for 62 cpm)
of duplex conveying switch 1 (DUPCSW1) turning on.
Duplex conveying switch 2 (DUPCSW2) does not turn off
within specified time <780 ms (570 ms) for 82 cpm/1000 ms
(570 ms) for 62 cpm> of duplex conveying switch 1
(DUPCSW1) turning off.
Duplex conveying switch 3 (DUPCSW3) does not turn on
within specified time (750 ms for 82 cpm/1000 ms for 62 cpm)
of duplex conveying switch 2 (DUPCSW2) turning on.
Duplex conveying switch 3 (DUPCSW3) does not turn off
within specified time (750 ms for 82 cpm/1000 ms for 62 cpm)
of duplex conveying switch 2 (DUPCSW2) turning off.
The original feed switch (OFSW) does not turn on within 3792
pulse during the second sheet feeding.
DP timing switch 2 (DPTM2) does not turn off within 3600
pulse.
DP timing switch 2 (DPTM2) does not turn on within 3600
pulse.
The original feed switch (OFSW) and original registration
switch (ORSW) does not turn off within 5000 pulse.
DP timing switch 1 (DPTM1) does not turn off within 2000
pulse.
DP timing switch 1 (DPTM1) does not turn on within 2000
pulse.
The original registration switch (ORSW) does not turn on
within 2000 pulse and after 5 retries.
" size.
1/2
Conditions
2KN/2KP
1-4-7