SNM-1001L Satellite Modem
Front Panel Operation
FUNCTION SELECT: UTILITY: SYSTEM: EXT AGC: MIN POWER
Sets the AGC voltage for a RX signal. The voltage range is 0.0 to 10.0V, in 0.5V steps. Upon
entry, the current external AGC voltage level is displayed. Press [↑] or [↓] to increment or
decrement the AGC voltage level in 0.5V steps. Press <ENTER> to execute the change.

FUNCTION SELECT: UTILITY: SYSTEM: MASTER RESET

Master reset function.
CAUTION
Select <ENTER>once to access HARD or SOFT.
1. Press [←] or [→] to make the selection.
2. Press <ENTER>.
3. Press [→] five times to move the cursor to YES.
4. Select YES and press <ENTER> again.
Note: The following parameters do not revert to default settings after a hard reset:
EXT AGC:
10.0 Volts
MASTER RESET
HARD/SOFT
Initiating a hard reset will reset the modem and calls the default
configuration settings from ROM. Initiating a soft reset will reset the
modem hardware, but saves the current configuration settings.
Address
Parity
Baud Rate
Remote Type

Ext AGC: Min Pwr

Ext AGC: Max Pwr
Display Contrast
MIN PWR
4–84
Revision 1