Electrical Safety - Comtech EF Data SNM-1001L Installation And Operation Manual

Table of Contents

Advertisement

SNM-1001L Satellite Modem
Preface
E
S
LECTRICAL
AFETY
The SNM-1001L Satellite Modem has been shown to comply with the following safety standard:
EN 60950: Safety of Information Technology Equipment, including electrical business
machines.
The equipment is rated for operation over the range 85 to 264 volts AC. It has a maximum
power consumption of 60 watts.
F
USES
The SNM-1001L Satellite Modem is fitted with two fuses, one each for line and neutral
connections. These are contained within the body of the IEC power connector, behind a small
plastic flap.
For 230 volt AC operation, use T0.75A, 20mm fuses.
For 115 volt AC operation, use T1.25A fuses, 20mm fuses.
For continued operator safety, always replace the fuses with the
correct type and rating.
IMPORTANT
Environmental
The SNM-1001L shall not be operated in an environment where the unit is exposed to
extremes of temperature outside the ambient range 0 to 50°C (32 to 122°F), precipitation,
condensation, or humid atmospheres above 95% RH, altitudes (un-pressurised) greater
than 2000 metres, excessive dust or vibration, flammable gases, corrosive or explosive
atmospheres.
Operation in vehicles or other transportable installations that are equipped to provide a
stable environment is permitted. If such vehicles do not provide a stable environment,
safety of the equipment to EN60950 may not be guaranteed.
xv
Revision 1
MN/SNM1001L.IOM

Advertisement

Table of Contents
loading