FUNCTION SELECT: MONITOR: CORRECTED BER

Displays the current corrected BER or "No Data" (if carrier is not locked).
Range: 1.0 E-3 to 1.0 E-12.
Notes:
1. Low limit is based on performance.
2. High limit is 1.0 E-12.
Press[←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement the
selected kbps. Press <ENTER> to execute the change.
FUNCTION SELECT: MONITOR:EB/NO
Displays the current E
Range: 2.0 to 16.0 dB.
Notes:
1. Low limit is based on the data rate.
2. High limit is 16.0 dB.
Press[←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement the
selected kbps. Press <ENTER> to execute the change.

FUNCTION SELECT: MONITOR: RECEIVE SIGNAL

CORRECTED BER
4.0
E-3
EB/NO
16.0 dB
/N
or "No Data" (if carrier is not locked).
b
0
RECEIVE SIGNAL
-45.0dBm