7) Remove the control panel.
8) Remove the two mounting screws
C. Pre-Exposure Lamp Unit
1. Removing the Pre-Exposure Lamp Unit
1) Open the front door, and slide out the hopper assembly; then, slide out the
fixing/feeding unit.
2) Remove the process unit. (See p. 7-18.)
3) Remove the primary charging assembly and the pre-transfer charging assembly.
4) Remove the blanking exposure lamp assembly.
5) Remove the two mounting screws
rail stay
.
COPYRIGHT © 1997 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
, and remove the standard white plate
Figure 4-307
, and remove the blanking exposure assembly
Figure 4-308
CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 4 IMAGE FORMATION SYSTEM
.