CHAPTER 11 TROUBLESHOOTING
Item
DPOT
Indicates the surface potential of the drum.
VAE
Indicates the average surface potential during AE
measurement.
VL1T
Indicates the VL1 (light area potential) target value.
VL1M
Indicates the VL1 (light area potential) measured
value.
VL2M
Indicates the VL2 (developing bias light area potential)
measured value.
VDT
Indicates the VD (dark area potential) target value.
VDM
Indicates the VD (dark area potential) measured
value.
11-164
COPYRIGHT © 1997 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
Screen 1-2
Description
CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
2/9
Remarks
Unit: V
Unit: V
Unit: V
Unit: V
Unit: V
Unit: V